Products

Contact Information

TEL: 0731-89895888

Address: Xiadopu Machinery Industrial Park, Ningxiang, Xiangjiang New District, Hunan Province

 

+
  • 1724338486480.jpg

Mining cable


as the name suggests, mining cable refers to the wire and cable used in mining industry. Mining cable will be used to connect shearer, conveyor and basic lighting communication equipment in coal mining industry. When mining cables are used in underground operation, jumper cables are usually used for high-voltage power supply lines. The weakest link in mining cable power supply is mining area power supply, and it is also in a place with bad environment. Therefore, when selecting mining cables, pay attention to the cross-sectional area of cable model and its safety, so as to ensure safety

Classification:

Cables for electrical equipment

Key words:

Product Introduction

Product application:

as the name suggests, mining cable refers to the wire and cable used in mining industry. Mining cable will be used to connect shearer, conveyor and basic lighting communication equipment in coal mining industry. When mining cables are used in underground operation, jumper cables are usually used for high-voltage power supply lines. The weakest link in mining cable power supply is mining area power supply, and it is also in a place with bad environment. Therefore, when selecting mining cables, pay attention to the cross-sectional area of cable model and its safety, so as to ensure safety

Product executive standard

MT818-2009 flame retardant cable for coal mine

Product model, name and purpose

Type Name Rated voltage purpose

MYJV

XLPE insulated PVC sheathed power cable for coal mine

8.7/10KVAnd below

It is mainly used for laying indoors, in tunnels and pipelines. The cable can not bear large external mechanical forces

MYJV22

Cross linked polyethylene insulated steel tape armored PVC sheathed power cable for coal mine

8.7/10KVAnd below

It is mainly used for laying in underground, indoor, tunnel and pipeline. It can bear considerable mechanical pressure, but can not bear large mechanical tension

MYJV32

Cross linked polyethylene insulated fine steel wire armored PVC sheathed power cable for coal mine

8.7/10KVAnd below

It is mainly used for laying in underground, indoor, tunnel and pipeline, and can bear considerable mechanical pressure and large mechanical tension

MVV

PVC insulated PVC sheathed power cables for coal mines

6/10KVAnd below

It is mainly used for laying indoors, in tunnels and pipelines. The cable can not bear large external mechanical forces

MVV22

PVC insulated steel tape armored PVC sheathed power cable for coal mine

6/10KVAnd below

It is mainly used for laying in underground, indoor, tunnel and pipeline. It can bear considerable mechanical pressure, but can not bear large mechanical tension

MVV32

PVC insulated fine steel wire armored PVC sheathed power cable for coal mine

6/10KVAnd below

It is mainly used for laying in underground, indoor, tunnel and pipeline, and can bear considerable mechanical pressure and large mechanical tension

 

Working conditions of the product

The maximum rated working temperature of the conductor of XLPE insulated cable is 90 ℃, and the maximum rated working temperature of the conductor of PVC insulated cable is 70 ℃

When XLPE insulated cable is short circuited (the longest duration shall not exceed 5S), the maximum temperature of cable conductor shall not exceed 250 ℃; In case of short circuit of PVC insulated cable (the longest duration shall not exceed 5S), the maximum temperature of cable conductor shall not exceed 160 ℃

The minimum bending radius of the cable is 15 times of the cable diameter

The working voltage of the system shall not be greater than 1.1 times of the rated voltage of  the system

When AC system is used, the rated voltage of the cable shall be at least equal to the standard voltage of the system. When used in DC system, the nominal voltage of the system shall not be greater than 1.5 times of the rated voltage of the cable

Bunched combustion test: when the nominal section of the power core is 50mm2 or above, it meets the requirements of class a bunched combustion test; When the nominal section of the power core is less than 50mm2, it meets the requirements of class B bunched combustion test

Message